| Sign In | Join Free | My insurersguide.com | 
 | 
Brand Name : VICTOR
Model Number : VICTOR 79A+
Certification : CE
Place of Origin : CHINA
MOQ : 1pcs
Price : 1pcs to 50pcs USD220/pc; 50pcs to 100pcs USD200/pc; 100pcs to 200pcs USD175/pc; above 200pcs USD160/pc
Payment Terms : T/T, Western Union, L/C, Paypal
Supply Ability : 3000pcs available
Delivery Time : 5 to 30 days
Packaging Details : 10pcs/Carton; Carton Size: 39.5*38.5*26cm; 12KG/carton
Color : Blue and Black
Display : Number: 5-digit display
Product Name : Process Multimeter
Work environment : 0~40°c, relative humidity ≤85%
Battery type : Three 1.5V (LR6) alkaline batteries
Battery low : lt is indicated with a battery mark
Weight : About 500g
Storage environment : -20°C-60 °c relative humidity below 90%
VICTOR 79A+ Digital Multimeter dual color plastic mold shell design and compliance with IP65 dust and waterproof grade 
  
  Basic characteristics of the product
  1. An industrial level on-site process maintenance tool combining a digital multi-meter with a process signal source.
  2. The product is used in harsh environments for the dual color plastic mold shell design and compliance with IP65 dust and
  waterproof grade.
  3. The product meets the safety standards of 600V CAT.IV and 1000V CAT.III.
  4. Basic characteristics of input measurement * Measurement functions: AC voltage, DC voltage, ohms, capacitance, DC current, AC
  current, Continuity, diode, frequency,thermocouple, and thermal resistance.
  * The measurement display reading is 55000 reading with a basic accuracy of 0.05%.
  * Measurement rate: fast 20 times/second, slow 5 times/second.
  * True AC RMS measurement, measurement bandwidth: 20Hz~1000Hz.
  * Manual or automatic range can be selected, and the measurement value display remains unchanged.
  * Relative value measurement (REL_ %)
  * Low pass filtering function (VFC) can accurately measure the voltage of frequency converters or other noise devices.
  
  5. Basic characteristics of analog output
  
  * The basic output accuracy is 0.05%, and the output display is 5 bits.
  * Output function: DC voltage, DC current, ohms, frequency, thermocouple, thermal resistance, SIMULATE function analog
  transmitter
  * When DC current outputs, both mA and % values can be displayed simultaneously. 25% and 100% manual stepping, automatic
  stepping, and automatic ramp current output functions
  * 24V loop power supply is provided internally.
  
  6. Loop detection function
  
  * Simultaneously supply 24V circuit power and measure current.
  * Built-in optional 250Ω HART loop resistor facilitates the use of HART communication devices without the need to carry load
  resistors separately.
  
  7. Built in temperature sensor, automatic cold-end compensation, and temperature display of ℃ or ℉.
  8. Manually set temperature cold-end compensation.
  9. Large screen LCD’s dual display with white LED backlight.
  10. Panel calibration technology is adopted for the instrument, which is connected to the standard instrument. The instrument
  panel calibration operation is carried out according to regulations. Moreover, corresponding calibration data is stored to
  complete the periodic calibration work of the instrument and ensure that it reaches the required accuracy and performance.
  11. Easy replacement of batteries and fuses is allowed for the battery compartment door.
  12. The instrument can be powered by four AA alkaline batteries or nickel hydrogen batteries in the battery compartment, or
  through a power adapter.
  13. Other functions: automatic power off, automatic backlight off, low battery detection, temperature unit setting, etc.
| Function | Range | Output setting scope | Resolution | Precision | Remark | 
| DC voltage DCV | 100mV | -10.00~110.00mV | 10μV | 0.2%+4 | Maximum output current 0.5mA | 
| 1000mV | -100.0~1100.0mV | 100μV | 0.2%+4 | Maximum output current 2mA | |
| 10V | -1.000~11.000V | 1mV | 0.2%+4 | Maximum output current 5mA | |
| DC current DCI | 30mA | 0.000~33.000mA | 0.001mA | 0.2%+4 | 20mA, maximum load1KΩ 30mA, maximum load600Ω | 
| Simulated transmitter SIMULATE | -30mA | 0.000~-33.000mA | 0.001mA | ||
| Loop power LOOP | 24V | ±10% | Maximum output current 35mA | ||
| OHM | 400Ω | 0.0Ω~400.0Ω | 0.1Ω | 0.2%+4 | Excitation current: ±0.5~3mA When excitation current is ±0.1~0.5mA, an additional error of 0.1Ω should be taken into account. The precision doesn’t include lead resistance. | 
| Thermocouple TC | R | 0°C~1767°C | 1°C | 0.2%+3°C(≤100℃) 0.2%+2°C(>100℃) | With the thermometric scale of ITS-90; The precision doesn’t include errors in cold-end compensation | 
| S | 0°C~1767°C | ||||
| B | 600°C~1820°C | ||||
| K | -200.0°C~1372.0°C | 0.1°C | 0.2%+2°C(≤-100℃) 0.2%+1°C(>-100℃) | ||
| E | -200.0°C~1000.0°C | ||||
| J | -200.0°C~1200.0°C | ||||
| T | -250.0°C~400.0°C | ||||
| N | -200.0°C~1300.0°C | ||||
| Thermal resistance RTD | PT100 | -0200.0~0850.0 | 0.1°C | 0.2%+0.6°C | 
 With the thermometric scale of Pt100-385; With excitation current of ±1mA The precision doesn’t include lead resistance. | 
| Cu50 | -050.0~150.0 | ||||
| Frequency FREQ | 100Hz | 1.0Hz~110.0Hz | 0.1Hz | 0.2%+2 | Rectangular wave, duty cycle of 50% 1~11Vp-p | 
| 1KHz | 0.100KHz~1.100KHz | 1Hz | 0.2%+2 | ||
| 10KHz | 1.0KHz~11.0KHz | 0.1KHz | 0.2%+2 | ||
| 1.Load characteristics: capacitive loads ≥0.01uF. | |||||











|   | 
| VICTOR 79A+ Professional Multifunction Process Calibrator Multimeter Digital Process Multimeter Images | 
 High Accuracy 10A Analog Digital Multimeter 500V Lcd Display
                                                                                    
                        
                        
                        
                                                            High Accuracy 10A Analog Digital Multimeter 500V Lcd Display
                                                    
                        
                     Handheld Smart Auto Range Digital Multimeter Continuity Test Anti Burning
                                                                                    
                        
                        
                        
                                                            Handheld Smart Auto Range Digital Multimeter Continuity Test Anti Burning
                                                    
                        
                     VC9208 Manual Range Digital Multimeter LCD Display With Backlight
                                                                                    
                        
                        
                        
                                                            VC9208 Manual Range Digital Multimeter LCD Display With Backlight
                                                    
                        
                     1000V 20A AC DC VICTOR Digital Multimeter True RMS With Temperature Frequency
                                                                                    
                        
                        
                        
                                                            1000V 20A AC DC VICTOR Digital Multimeter True RMS With Temperature Frequency
                                                    
                        
                     Auto Range VICTOR 88A Pocket Size Digital Multimeter 3999 Counts With True RMS
                                                                                    
                        
                        
                        
                                                            Auto Range VICTOR 88A Pocket Size Digital Multimeter 3999 Counts With True RMS
                                                    
                        
                     Small Type VICTOR Digital Multimeter Resistance Capacitance Frequency Temperatur
                                                                                    
                        
                        
                        
                                                            Small Type VICTOR Digital Multimeter Resistance Capacitance Frequency Temperatur
                                                    
                        
                     True RMS VICTOR Digital Multimeter Auto Range 1000V 20A AC DC
                                                                                        
                                                        
                        
                        
                        
                                                            True RMS VICTOR Digital Multimeter Auto Range 1000V 20A AC DC
                                                    
                        
                     6000 Counts Industrial True Rms Multimeter With Temperature Backlight
                                                                                    
                        
                        
                        
                                                            6000 Counts Industrial True Rms Multimeter With Temperature Backlight
                                                    
                        
                     VICTOR 98A+ VICTOR Digital Multimeter 22000 counts display auto range multimeter
                                                                                    
                        
                        
                        
                                                            VICTOR 98A+ VICTOR Digital Multimeter 22000 counts display auto range multimeter
                                                    
                        
                     Digital Multimeter Process Calibrator Signal Source CAT IV 600V With 40MΩ
                                                                                    
                        
                        
                        